radtechsociety.blogspot.com
Nuclear Arrangement | RADTECH 111
http://radtechsociety.blogspot.com/2012/11/nuclear-arrangement.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. 183; Posted by Joseph Causapin. Es – atoms or elements that have the same # of protons; same element/atomic number, different mass number. Rs – atoms or elements that have the same atomic mass. Es – atoms or elements that have the same # of neutrons. Rs – atoms or elements that have the same atomic mass and atomic number but differs in energy levels. Note: Use the mnemonic PANE.
radtechsociety.blogspot.com
November 2012 | RADTECH 111
http://radtechsociety.blogspot.com/2012_11_01_archive.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. 183; Posted by Joseph Causapin. Three Principal Parts of an X- ray Imaging System. The part of the x-ray imaging system most familiar to the radiologic technologist is the operating console. The operating console allows the radiologic technologist to control the x-ray tube current and voltage so that the useful x-ray beam is of proper quantity and quality. Most operating consoles ...
radtechsociety.blogspot.com
Control of Scatter Radiation | RADTECH 111
http://radtechsociety.blogspot.com/2012/11/control-of-scatter-radiation.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. Control of Scatter Radiation. 183; Posted by Joseph Causapin. Effect of Scatter Radiation on Image Contrast. One of the most important characteristics of image quality is contrast,. Even under the most favorable conditions, most remnant x-rays. When primary x-rays interact with the patient, x-rays are scattered from the patient in all directions. Dental radiography represents anot...
radtechsociety.blogspot.com
Models of Atom | RADTECH 111
http://radtechsociety.blogspot.com/2012/11/models-of-atom.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. 183; Posted by Joseph Causapin. 8211; his model showed that the elements could be classified as to integral values of atomic mass. Elements were composed of identical atoms acting the same way. In a chemical reaction. 8220;hook and eye model “to account for chemical combination. Developed the first periodic table of elements. Introduced the nuclear model. 171; Older Post.
radtechsociety.blogspot.com
X-ray Imaging System | RADTECH 111
http://radtechsociety.blogspot.com/2012/11/x-ray-imaging-system.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. 183; Posted by Joseph Causapin. Three Principal Parts of an X- ray Imaging System. The part of the x-ray imaging system most familiar to the radiologic technologist is the operating console. The operating console allows the radiologic technologist to control the x-ray tube current and voltage so that the useful x-ray beam is of proper quantity and quality. Most operating consoles ...
radtechsociety.blogspot.com
Characteristics of Several Types of Ionizing Radiation | RADTECH 111
http://radtechsociety.blogspot.com/2012/11/characteristics-of-several-types-of.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. Characteristics of Several Types of Ionizing Radiation. 183; Posted by Joseph Causapin. Up to 0.1 mm. 171; Older Post. Subscribe to: Post Comments (Atom). Characteristics of Several Types of Ionizing Radia. Control of Scatter Radiation. Vertebrae and Its Localization Point. Topographical Landmarks in the Body. Radiographic Planes and Positions. View my complete profile.
radtechsociety.blogspot.com
September 2014 | RADTECH 111
http://radtechsociety.blogspot.com/2014_09_01_archive.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. The X- ray Tube. 183; Posted by Joseph Causapin. 3 External structures of an x-ray tube. Glass or metal envelope. Internal structure of an x-ray tube. Made up of CATHODE and ANODE enclose in a vacuum. 6 ways to support x-ray tube. Portable or mobile machines. Most frequently used system. Consists of two sets of rails mounted to the ceiling directly over the radiographic table.
radtechsociety.blogspot.com
The X- ray Tube | RADTECH 111
http://radtechsociety.blogspot.com/2014/09/the-x-ray-tube.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. The X- ray Tube. 183; Posted by Joseph Causapin. 3 External structures of an x-ray tube. Glass or metal envelope. Internal structure of an x-ray tube. Made up of CATHODE and ANODE enclose in a vacuum. 6 ways to support x-ray tube. Portable or mobile machines. Most frequently used system. Consists of two sets of rails mounted to the ceiling directly over the radiographic table.
radtechsociety.blogspot.com
Scatter Radiation | RADTECH 111
http://radtechsociety.blogspot.com/2012/11/scatter-radiation.html
Radiologic Physics, Image Evaluation, Radiographic Positioning and Procedures, Anatomy and Physiology, Radiological Sciences. 183; Posted by Joseph Causapin. Scatter radiation is a secondary radiation produced when an x- ray interact with the patient and the energy is not enough for an x- ray to reach the IR. X-rays that exit from the patient are remnant x-rays and those that exit and interact with the image receptor are called. Others interact with the patient and are absorbed (b). X-rays of types c.
SOCIAL ENGAGEMENT