masterthatchers.co.uk
Thatching links from Master thatchers.co.uk - Nationwide Master thatchers
http://masterthatchers.co.uk/links.html
Telephone: 023 8087 3628. We have included a selection of thatching links below that we feel are of benefit to thatched property owners. Free and impartial advice on anything thatch related. Fire retardant spray for thatch. Peace of mind and insurance premium reductions. LABC approved fire retardant barrier for thatch. SMF Crouch and Co Ltd. Est30yrs Nationwide Master Thatcher. Thatching craftsman based in the south. Specialist insurers who offer premium reductions on roofs sprayed with Magma Firestop.
thatch-safe.co.uk
Thatch-Safe® Model - Thatch Safe
http://www.thatch-safe.co.uk/about-thatch-safe/thatch-safe-model
The Dorset Model and Building Regulations. As we can see from the diagram, the Thatch-Safe sits on the rafters and under the thatch. This provides a barrier between the thatch and the roof structure with no counter battening required due to the breathability of Thatch-Safe . Thatch-Safe is flexible so it is easy to fit around windows and in valleys. It can also be double wrapped around the chimney reducing the risk of heat transfer from the chimney. For more information on Magma Firestop.
thatch-safe.co.uk
THATCH-SAFE® Application Instructions - Thatch Safe
http://www.thatch-safe.co.uk/about-thatch-safe/thatch-safe-application-instructions
The Dorset Model and Building Regulations. Please follow the below instructions when fitting the THATCH-SAFE product to your roof. One layer of THATCH-SAFE to be laid, Aluminium side uppermost, over the rafters. To be secured by battens 50mm x 20mm at 250mm intervals. The battens are to be fixed by 3 inch galvanised nails to the rafters. All joins to be overlapped by 100mm and where are secured by an extra batten. Roofs need to breathe. Roofs need to breathe. SMF Crouch and Co Ltd. NFU Fire Safety Advice.
thatch-safe-attix.co.uk
Useful Links from -THATCH-SAFE ATTIX
http://thatch-safe-attix.co.uk/links.html
Assess the risk and design the installation. Personalised to your property. Ensuring lasting protection . Relating to Thatch Fire Safety. Fire barrier for thatched properties LABC approved. Fire retardant spray for thatch. See Magma demonstrated on Grand Designs. SMF Crouch and Co. Hampshire based Master Thatchers and Thatch-Safe distributor. The Thatch Advice Centre. Free advice on all things thatch. Main US production site.
masterthatchers.co.uk
Thatching Materials from Master thatchers.co.uk - Nationwide Master thatchers
http://masterthatchers.co.uk/materials.html
Telephone: 023 8087 3628. There are three main types of thatching materials involved in thatching a roof. All three vary in both look application method and how long they will last. But as an environmentally friendly building solution, thatch offers an aesthetically pleasing alternative to the standard roof tile. Long Straw in the field. Heather,Turf, Sedge, Rye Straw and Veldt Grass. As Fire retardant specialists Master Thatchers.co.uk. SMF Crouch and Co Ltd. Flexible insulating fire barrier.
masterthatchers.co.uk
Master thatchers.co.uk - Nationwide Master thatchers
http://masterthatchers.co.uk/index.html
Telephone: 023 8087 3628. Welcome to Simon Crouchs' Website. I am a Master Thatcher with over 30 years experience of working with all materials. All over the UK. My team of Master Thatchers are craftsmen and we offer a thatching service. Covering all aspects of thatching. From New build to listed properties, total re-thatch to repairs. We are happy to discuss client requirements with Architects, Conservation Officers and builders. As Master Thatchers we are the UK distributor of Magma Firestop.
thatch-safe.co.uk
Thatch-Safe® - Thatch Safe
http://www.thatch-safe.co.uk/about-thatch-safe
The Dorset Model and Building Regulations. Thatch-Safe is a layered product designed especially for thatch which has had LABC (National Building Control Approval) since 2008. It is a flexible barrier (1M X 5M) which is placed horizontally over the rafters and under the thatch. Thatch-Safe meets building regulations for new build (as the Dorset Model) but has added value, namely:. Thatch-Safe has both 1/2 hour fire resistance and 1 hour fire integrity. The lack of counter battening required to fix, means ...
thatch-safe.co.uk
Properties - Thatch Safe
http://www.thatch-safe.co.uk/about-thatch-safe/thatch-safe-properties
The Dorset Model and Building Regulations. Fire Barrier designed especially for Thatched Roofs (in consultation with Master Thatchers, Fire Retardant Manufacturers, Insurers, Architects, Builders, Councils and Fire-Brigades). Tested to Hour Insulation, 1 Hour Integrity and for Vapour Permeability. The insulation (this product is 20mm thick) is sandwiched between the foil and the reinforcing wire mesh. With the thatch, 0.2µ value is easily achieved. Roofs need to breathe. Roofs need to breathe. New Forest...
wessexthatchers.com
Wessex Thatchers Services, Master Thatcher in Hampshire
http://www.wessexthatchers.com/wessex-thatcher-services
Wessex Thatchers offer a complete thatching service to its clients. From discussions on plans for new thatched properties to repairs to old listed buildings, we are happy to talk to you about your requirements and work out the best and most cost effective thatching solution. See below for more information on Thatch Fire Protection, Thatching Materials and Thatch lifespan. Discussion on your thatched property and your requirements. Assistance to architects on planning for thatched extensions and new builds.