mytrystwithsteamturbine.blogspot.com mytrystwithsteamturbine.blogspot.com

mytrystwithsteamturbine.blogspot.com

My tryst with Steam Turbine

My tryst with Steam Turbine. My experience with Steam Turbine. Friday, June 6, 2014. Why most people think that -0.9 Kg/cm2 gauge is the correct value of Condenser Vacuum? Most Steam Turbines in India are designed considering Cooling Water Inlet Temperature of 33 degC and temperature rise of 9 degC through the Condenser. Assuming Terminal Temperature Difference (TTD) of 4 degC the saturation temperature at Turbine exhaust works out as follows. CW Inlet Temperature Temperature rise through Condenser TTD.

http://mytrystwithsteamturbine.blogspot.com/

WEBSITE DETAILS
SEO
PAGES
SIMILAR SITES

TRAFFIC RANK FOR MYTRYSTWITHSTEAMTURBINE.BLOGSPOT.COM

TODAY'S RATING

>1,000,000

TRAFFIC RANK - AVERAGE PER MONTH

BEST MONTH

November

AVERAGE PER DAY Of THE WEEK

HIGHEST TRAFFIC ON

Saturday

TRAFFIC BY CITY

CUSTOMER REVIEWS

Average Rating: 3.9 out of 5 with 17 reviews
5 star
8
4 star
3
3 star
4
2 star
0
1 star
2

Hey there! Start your review of mytrystwithsteamturbine.blogspot.com

AVERAGE USER RATING

Write a Review

WEBSITE PREVIEW

Desktop Preview Tablet Preview Mobile Preview

LOAD TIME

0.6 seconds

FAVICON PREVIEW

  • mytrystwithsteamturbine.blogspot.com

    16x16

  • mytrystwithsteamturbine.blogspot.com

    32x32

  • mytrystwithsteamturbine.blogspot.com

    64x64

  • mytrystwithsteamturbine.blogspot.com

    128x128

CONTACTS AT MYTRYSTWITHSTEAMTURBINE.BLOGSPOT.COM

Login

TO VIEW CONTACTS

Remove Contacts

FOR PRIVACY ISSUES

CONTENT

SCORE

6.2

PAGE TITLE
My tryst with Steam Turbine | mytrystwithsteamturbine.blogspot.com Reviews
<META>
DESCRIPTION
My tryst with Steam Turbine. My experience with Steam Turbine. Friday, June 6, 2014. Why most people think that -0.9 Kg/cm2 gauge is the correct value of Condenser Vacuum? Most Steam Turbines in India are designed considering Cooling Water Inlet Temperature of 33 degC and temperature rise of 9 degC through the Condenser. Assuming Terminal Temperature Difference (TTD) of 4 degC the saturation temperature at Turbine exhaust works out as follows. CW Inlet Temperature Temperature rise through Condenser TTD.
<META>
KEYWORDS
1 posted by
2 kamalakar agashe
3 no comments
4 email this
5 blogthis
6 share to twitter
7 share to facebook
8 share to pinterest
9 labels atmospheric pressure
10 barometric pressure
CONTENT
Page content here
KEYWORDS ON
PAGE
posted by,kamalakar agashe,no comments,email this,blogthis,share to twitter,share to facebook,share to pinterest,labels atmospheric pressure,barometric pressure,condenser vacuum,durgapur,jsw energy,poor vacuum,ratnagiri,torangallu,turbine back pressure
SERVER
GSE
CONTENT-TYPE
utf-8
GOOGLE PREVIEW

My tryst with Steam Turbine | mytrystwithsteamturbine.blogspot.com Reviews

https://mytrystwithsteamturbine.blogspot.com

My tryst with Steam Turbine. My experience with Steam Turbine. Friday, June 6, 2014. Why most people think that -0.9 Kg/cm2 gauge is the correct value of Condenser Vacuum? Most Steam Turbines in India are designed considering Cooling Water Inlet Temperature of 33 degC and temperature rise of 9 degC through the Condenser. Assuming Terminal Temperature Difference (TTD) of 4 degC the saturation temperature at Turbine exhaust works out as follows. CW Inlet Temperature Temperature rise through Condenser TTD.

INTERNAL PAGES

mytrystwithsteamturbine.blogspot.com mytrystwithsteamturbine.blogspot.com
1

My tryst with Steam Turbine: Effect of Atmospheric Pressure on measurement of Condenser Vacuum.

http://www.mytrystwithsteamturbine.blogspot.com/2013/06/effect-of-atmospheric-pressure-on.html

My tryst with Steam Turbine. My experience with Steam Turbine. Wednesday, June 12, 2013. Effect of Atmospheric Pressure on measurement of Condenser Vacuum. I have following measurements of Condenser Vacuum for 210 MW units in two locations:. Tuticorin TPS -662 mmHg CW Inlet 33.15 degC outlet 43.3 degC. Nasik TPS -658 mmHg CW Inlet 28.3 degC outlet 36.15 degC. The absolute pressure for the measurement would be:. Tuticorin -662 760 = 98 mmHg = 130 mbar. Nasik -658 712 = 54 mmHg = 72 mbar. Please note that ...

2

My tryst with Steam Turbine: Beware! Steam Turbine Deposits of 1929 to 1936 have surfaced once again.

http://www.mytrystwithsteamturbine.blogspot.com/2013/02/beware-steam-turbine-deposits-of-1929.html

My tryst with Steam Turbine. My experience with Steam Turbine. Wednesday, February 27, 2013. Steam Turbine Deposits of 1929 to 1936 have surfaced once again. At one IPP in India H. P. Heater Safety Valve blew when the machine suddenly touched 103.6% of rated load. Maintenance Engineer thought that the original Safety Valve setting could have been disturbed but on checking the data in DCS it was found that the extraction pressure had actually reached the set value of Safety Valve to blow. Engineering Expe...

3

My tryst with Steam Turbine: May 2013

http://www.mytrystwithsteamturbine.blogspot.com/2013_05_01_archive.html

My tryst with Steam Turbine. My experience with Steam Turbine. Tuesday, May 14, 2013. Pump assisted Siphon in CW System of Turbine. To understand the content of this post please read Wikipedia Page on Siphon. Once through CW systems are relatively unknown in Thermal Power Plants being constructed today but there are many old ones. Let us look at following image on Wikipedia page. B can be the top point of Condenser Water Box and C the end of the outlet pipe. Once through Cooling Water. Pump assisted Siph...

4

My tryst with Steam Turbine: January 2013

http://www.mytrystwithsteamturbine.blogspot.com/2013_01_01_archive.html

My tryst with Steam Turbine. My experience with Steam Turbine. Sunday, January 13, 2013. Required Dew point of air for Gas tightness test of Generator and of Hydrogen when unit is running. I also checked it at 4 barg air pressure and the value is 14.9 degC. Is it ok to fill this air? NO This is winter season and the temperature of air will go below 14.9 degC resulting into moisture in Generator. Is a handy tool to convert. The converted Dew Point should be atleast 20 degC below the Gas Temperature.

5

My tryst with Steam Turbine: Why most people think that -0.9 Kg/cm2 gauge is the correct value of Condenser Vacuum?

http://www.mytrystwithsteamturbine.blogspot.com/2014/06/why-most-people-think-that-09-kgcm2.html

My tryst with Steam Turbine. My experience with Steam Turbine. Friday, June 6, 2014. Why most people think that -0.9 Kg/cm2 gauge is the correct value of Condenser Vacuum? Most Steam Turbines in India are designed considering Cooling Water Inlet Temperature of 33 degC and temperature rise of 9 degC through the Condenser. Assuming Terminal Temperature Difference (TTD) of 4 degC the saturation temperature at Turbine exhaust works out as follows. CW Inlet Temperature Temperature rise through Condenser TTD.

UPGRADE TO PREMIUM TO VIEW 11 MORE

TOTAL PAGES IN THIS WEBSITE

16

OTHER SITES

mytrystwithfoodandtravel.blogspot.com mytrystwithfoodandtravel.blogspot.com

My Tryst With Food And Travel

My Tryst With Food And Travel. WORLD ON MY PLATE. My Tryst With Food And Travel. CULINARY ADVENTURE IN YOUR KITCHEN. Saturday, 15 August 2015. TRI COLOUR PARFAIT - CELEBRATING A STEP TOWARDS A HEALTHIER and PEACEFUL INDIA ON THE 69TH INDEPENDENCE DAY. PIYALI SEKHAR MUTHA /My Tryst With Food And Travel. WORLD ON MY PLATE. Monday, 10 August 2015. RAIBI / MOROCCAN YOGURT DRINK WITH MANGO GINGER, COCONUT AND FRESH ROSE PETALS FLOAT - MY DATE WITH BOGART AND CASABLANCA. THE WORLD ON MY PLATE. WORLD ON MY PLATE.

mytrystwithlife.blogspot.com mytrystwithlife.blogspot.com

/home/saurabh

Software Libre,Linux,Rails,VMs and More. Wednesday, September 03, 2008. Usr/bin/gem:23: uninitialized constant Gem: GemRunner (NameError). Recently I ran an update to my Ruby Gems using the following command. Sudo gem update - system. And I got this strange Error:. Usr/bin/gem:23: uninitialized constant Gem: GemRunner(NameError). I googled and found a fix to this problem. Add the line in bold to the file /usr/bin/gem:. See LICENSE.txt for permissions. Unless required version.satisfied by? The Script abov...

mytrystwithmakeup.blogspot.com mytrystwithmakeup.blogspot.com

My Tryst with Makeup

My Tryst with Makeup. A budding makeup and beauty blog. Thursday, 18 June 2015. Maybelline Color Show Bright Sparks Nail Color- Power Of Red Review. Tell me a nail paint lover who doesn't love red nails. I believe that a nail polish collection is incomplete without a classic red nail paint.( I own three reds). A red manicure exudes sexiness and boldness. It is such a festive colour too, and utterly feminine. Here i am reviewing this one called Power of Red from the Maybelline Bright Sparks range. 7 Maybe...

mytrystwithsteamturbine.blogspot.com mytrystwithsteamturbine.blogspot.com

My tryst with Steam Turbine

My tryst with Steam Turbine. My experience with Steam Turbine. Friday, June 6, 2014. Why most people think that -0.9 Kg/cm2 gauge is the correct value of Condenser Vacuum? Most Steam Turbines in India are designed considering Cooling Water Inlet Temperature of 33 degC and temperature rise of 9 degC through the Condenser. Assuming Terminal Temperature Difference (TTD) of 4 degC the saturation temperature at Turbine exhaust works out as follows. CW Inlet Temperature Temperature rise through Condenser TTD.

mytrystwiththoughts.blogspot.com mytrystwiththoughts.blogspot.com

Tryst With My Thoughts......

Tryst With My Thoughts. May 3, 2016. One Last Promise - Before I do. It's hard to confess for a person like me that yes I was scared while waking towards you as a bride to be. I was scared that will I be able to hold your hand in all the storms that will come? Will a extravagant like me will be able to save penny for our first house? Will a messed up person like me will be able to shape up your life? Will I be able to stand strong between you and your wish ,if the wish is not in best of your intrest?

mytryz.com mytryz.com

My Tryz | testing 123

Rev slider vc alias="gaming"]. Vc row][vc column width=”1/3″]. Vc column][vc column width=”1/3″]. Vc column][vc column width=”1/3″]. Vc column][vc column width=”1/3″]. Few Words About Store. We think we are pretty friendly, but here’s the place that will answer any question or query you may have, from placing a new order, any issue you may have with an existing order, or helping you join our thriving community of gamers. Safe and secure shopping. Team of highly skilled engineers. Talion finds himself res...

mytrzy.pun.pl mytrzy.pun.pl

My TRZY

Czyli Agata, Paulina, Zuzia. Wszystkie promocje komputronik w jednym miejscu! 2008-12-05 15:34:21 przez Zuzka17. 2009-04-07 18:12:44 przez agata12. 3 rzeczy Suknia usta fryzura. 2009-01-16 15:47:37 przez Zuzka17. Kto by nie chciał. 2008-12-21 10:33:37 przez Zuzka17. 2009-01-16 16:05:16 przez Zuzka17. 2008-12-11 10:40:20 przez Zuzka17. 2008-12-07 10:49:58 przez Zuzka17. 2009-04-07 18:15:15 przez agata12. 2008-12-22 13:52:02 przez Zuzka17. 2009-01-02 21:55:31 przez Zuzka17. 277) * paulina *.