transformertechnology.blogspot.com
Transformer Technology (TRANSTECH): TRANSFORMER TESTING AT SITE
http://transformertechnology.blogspot.com/2009/06/transformer-testing-at-site.html
The way to explore the Technologies using in Transformer. Welcomes you to world of Electrical Transformers. Monday, June 15, 2009. TRANSFORMER TESTING AT SITE. Everyone knows before commissioning or charging any equipment it must be need to test before putin to service, like that the new transformer is also need to ensure everything is fine. So, some tests are required to confirm. those are all called Pre-commissioning tests.some important tests are mentioned here for easy ref,. Ii) Turns / voltage Ratio.
transformertechnology.blogspot.com
Transformer Technology (TRANSTECH): PHASE - PHASE & PHASE - EARTH CLEARANCES IN AIR
http://transformertechnology.blogspot.com/2009/06/phase-phase-phase-earth-clearances-in.html
The way to explore the Technologies using in Transformer. Welcomes you to world of Electrical Transformers. Wednesday, June 17, 2009. PHASE - PHASE and PHASE - EARTH CLEARANCES IN AIR. Engineers who are all working in Project as electrical cable, line works, installations etc. must know the clearances between phase - ph and also ph- earth to maintain the minimum values. VERBAND DER ELEKTROTEKNIK ELECTRONIK INFORMATIONS TECHNIK. Central Board of Irrigation and Power. I hope this may helpful to you all Eng...
transformertechnology.blogspot.com
Transformer Technology (TRANSTECH): TERTIARY WINDING (Third Winding)
http://transformertechnology.blogspot.com/2009/06/tertiary-winding-third-winding.html
The way to explore the Technologies using in Transformer. Welcomes you to world of Electrical Transformers. Friday, June 19, 2009. TERTIARY WINDING (Third Winding). Tertiary / Stabilizing Winding:. In transformers there are two windings primary and secondary, but in some case you may see in addition to them one more winding named as tertiary winding. Used to reduce the interference with communication circuit due to third harmanic currents in the lines and earth. Subscribe to: Post Comments (Atom). The Wo...
transformertechnology.blogspot.com
Transformer Technology (TRANSTECH): May 2012
http://transformertechnology.blogspot.com/2012_05_01_archive.html
The way to explore the Technologies using in Transformer. Welcomes you to world of Electrical Transformers. Friday, May 25, 2012. MOM of Vestas, Chitradurga. Subscribe to: Posts (Atom). MOM of Vestas, Chitradurga. Never, put your banana in the refrigerator. The World of Networking. There was an error in this gadget.
networksking.blogspot.com
The World of Networking: Mac frame format
http://networksking.blogspot.com/2008/08/mac-frame-format.html
The World of Networking. Tuesday, August 5, 2008. Let us take a closer look at the Mac frame format. The Preamble is a seven byte field made up of alternating 0's and 1's which is very essential for synchronization between the transmitter and the receiver. Start frame delimiter has a fixed sequence 10101011 which indicates the start of a frame and identifies the first bit for the receiver. The Destination address is either 2byte or 6byte which refers to the address of the receiving system.
networksking.blogspot.com
The World of Networking: IP Address
http://networksking.blogspot.com/2008/08/ip-address.html
The World of Networking. Tuesday, August 12, 2008. Just like every home has an address every node in the network has a unique address. IP address is the address used for communication between the computers at the network layer level. Every computer linked to the web will be allotted a 32 bit IP address during start up. The IP address can be broadly classified as two types namely classful and classless addressing. Let us take a look at the classful addressing. August 13, 2008 at 6:02 AM. Thanks for adding...
transformertechnology.blogspot.com
Transformer Technology (TRANSTECH): BUSHING METAL PART MELTING
http://transformertechnology.blogspot.com/2009/06/bushing-metal-part-melting.html
The way to explore the Technologies using in Transformer. Welcomes you to world of Electrical Transformers. Monday, June 15, 2009. BUSHING METAL PART MELTING. Electrical Connections are very important if they improper it may cost the following effects on man and materials, and ready to destroy the whole system also, The poor connection in Bushing metal part causes the following,. Melting in any side of connections, usually low melting point material side. Over heating in contact places.
transformertechnology.blogspot.com
Transformer Technology (TRANSTECH): Transformer Efficiency
http://transformertechnology.blogspot.com/2009/07/transformer-efficiency.html
The way to explore the Technologies using in Transformer. Welcomes you to world of Electrical Transformers. Friday, July 10, 2009. Efficiency = Output / Input. Input - Losses) / Input. 1- (Losses / Input) ; input = VI cos θ ; (say, losses/ VI = x). Efficiency = 1 - (x/ (cos θ x). 1 - ( x/cos θ)/(1 x/cos θ). Efficiency = (VA * cos θ) / ( VA * cos θ) Losses) * 100. Transformer KVA = 1000 KVA; 11 KV/ 433 V, Full loadLosses measured = 12.5 KW. Calculate efficiency in full load at .8 PF, .9 PF and UPF.
transformertechnology.blogspot.com
Transformer Technology (TRANSTECH): June 2009
http://transformertechnology.blogspot.com/2009_06_01_archive.html
The way to explore the Technologies using in Transformer. Welcomes you to world of Electrical Transformers. Friday, June 19, 2009. TERTIARY WINDING (Third Winding). Tertiary / Stabilizing Winding:. In transformers there are two windings primary and secondary, but in some case you may see in addition to them one more winding named as tertiary winding. Used to reduce the interference with communication circuit due to third harmanic currents in the lines and earth. IMPORTANCE OF PERCENTAGE IMPEDANCE. For tr...
transformertechnology.blogspot.com
Transformer Technology (TRANSTECH): MAGNETIC BALACE TEST
http://transformertechnology.blogspot.com/2009/06/magnetic-balace-test.html
The way to explore the Technologies using in Transformer. Welcomes you to world of Electrical Transformers. Monday, June 15, 2009. Magnetic Balance test used to find the distribution of Flux (Magnetic), Core Assembly Condition and defect in winding (If any). It may check at HV Side or LV Side as per requirement/ site condition. For Delta connections, apply voltage must be in Phase - Phase like U and V, V and W and W and U. U and N = (V and N) (W and N); 240 = 198 42. Magnetic Balance at HV side.